Illustrated title card for the guide: RG59 vs RG6 vs RG11: EoC Distance and PoE Wattage
coax networking

RG59 vs RG6 vs RG11: EoC Distance and PoE Wattage

Compare RG59, RG6 and RG11 Ethernet-over-coax distances, see how PoE watts drop over longer runs, and check whether your cable can power a camera.

For Ethernet over coax (EoC), Veracity lists up to 300 m on RG59, 400 m on RG6 and 500 m on RG11 for its HIGHWIRE Powerstar pair at 100Base-TX. For PoE, check your camera’s wattage against the range table for your exact cable and power source. Veracity specifications

Published Ethernet-over-coax distances

Both manufacturers list RG11 as the longest-reaching cable in these product specifications, with RG6 in the middle. These are the published coax distances for the named equipment. Veracity HIGHWIRE Powerstar · GeoVision GV-POC0100

CableVeracity HIGHWIRE Powerstar Base and CameraGeoVision GV-POC0100 transmitter and receiver
RG59300 m100 m (4V2C)
RG6400 m180 m (5C2V)
RG11500 m230 m (7C)

Veracity lists up to 25 W of camera PoE for the pair and specifies a 57 V DC supply at the base for maximum PoE delivery. Use the distance and camera power limits together when sizing a run. Veracity specifications

PoE wattage by distance

These are the published PoE outputs for the REPOTEC RP-EC509CP/T when the link is powered by an 802.3at PoE switch. All three distances are within the 100 Mbps reach listed separately for RG59 (75-3) and RG6U (75-5). REPOTEC power and transmission distance tables

Coax lengthRG59 outputRG59 drop from 100 mRG6U outputRG6U drop from 100 m
100 m19 WBaseline20 WBaseline
200 m17 W2 W20 W0 W
300 m15 W4 W19 W1 W

The drop columns compare the adapter’s output across distances. At 300 m, subtract 15 W from the 19 W RG59 baseline for a 4 W drop. For RG6U, 20 W minus 19 W gives a 1 W drop. REPOTEC output figures

For an input-to-output comparison, REPOTEC lists 50 W at the input and 24 W at the output on 300 m of RG59 with a 56 V power adapter. The 26 W difference spans the full extender link, from the input of one unit to the output of the other. REPOTEC input and output figures

Check your run against the tables

  1. Record the coax run length and RG type. For the RP-EC509CP, check the listed reach for your cable type and target data rate. Use REPOTEC’s PoE output table for your cable type and power source. REPOTEC distance specifications
  2. For an Axis camera, look up its maximum PoE consumption in the datasheet. Include expected Ethernet cable loss in the camera’s power budget. Axis camera power guidance
  3. For an output table like REPOTEC’s, compare the listed output at your run length with the camera’s power budget. REPOTEC output table

Evidence and limits. The HIGHWIRE Powerstar, GV-POC0100 and RP-EC509CP documentation and Axis’s December 2025 camera power white paper were checked on November 26, 2026. The examples use published figures and arithmetic. The equipment and cabling were not tested for this article.

Sources

The published documentation this guide was built from.

  1. Veracity HIGHWIRE Powerstar Base veracityglobal.com
  2. GeoVision GV-POC0100 product specifications geovision.com.tw
  3. REPOTEC RP-EC509CP power and transmission distance repotec.com
  4. Axis white paper on typical and maximum camera power whitepapers.axis.com

Related guides