For a CCTV retrofit over RG59 or RG6, start with the Veracity HIGHWIRE Powerstar Base and Camera pair if you need a 100 Mbps link within its published range. Pick SC&T IP09CP for a longer run that fits its speed and camera-end power limits. Veracity, SC&T
Compare PoE over coax converters
| Converter | Best fit | Published coax performance | Power and compatibility |
|---|---|---|---|
| Veracity HIGHWIRE Powerstar, VHW-HWPS-B and VHW-HWPS-C | A single camera that needs full-duplex 100Base-TX | Up to 300 m on RG59 or 400 m on RG6 at full link rate | Up to 25 W for the camera. The Base accepts PoE. For maximum PoE delivery, power the Base with a 57 V DC supply. Veracity Base, Camera |
| SC&T IP09CP | A longer run where the camera’s bitrate fits the link speed | Up to 500 m at 100 Mbps on RG59 or RG6U. At 10 Mbps, up to 800 m on RG59 or 1,000 m on RG6U. | Available PoE falls with distance. Choose PoE switch power or an external DC adapter for the transmitter or receiver. Connecting a PoE switch and a DC adapter together can damage the equipment. SC&T |
Match the converter to your cable and camera
- Identify the coax and record the run length. Check whether the cable is RG59 or RG6. Inspect the coax and its BNC connectors. Match the cable type and length to the chosen model’s figures. SC&T power guide, SC&T IP09CP
- Check the camera’s PoE standard, maximum power and required bandwidth. Include the camera’s peak draw with features such as infrared LEDs, a heater or pan-tilt-zoom enabled, if fitted. If multiple runs share a PoE switch, check its total power budget as well. SC&T power guide
- Check power at the camera end. Use the vendor’s figures for your cable, distance and power source. Compare the available wattage at the camera with the camera’s maximum draw. SC&T power guide
Wire and check the first camera
For a Veracity HIGHWIRE Powerstar setup powered by PoE, place the Base at the switch and the Camera adapter at the IP camera. Connect the two adapters over the existing coax. Veracity Base, Veracity Camera, Axis white paper
PoE switch → Ethernet → Base → coax → Camera adapter → Ethernet → PoE IP camera
If the SC&T IP09CP link stays down, check the power LEDs and try a 1 m coax jumper on the bench to isolate a problem with the installed run. SC&T IP09CP
If you want to keep the analog cameras, use a video encoder to digitize their feeds for the IP network. The converter pairs above are for running replacement IP cameras over the old coax. Axis white paper
Evidence and limits. The linked manufacturer documentation for the listed models and Axis’s March 2021 white paper were checked on November 27, 2026. No installation or performance tests were conducted for this guide.